331+ free tools. No sign-up. No hidden fees. Explore the toolkit

BTU Calculator

An air conditioner or heater that is too small runs all day and never catches up; one that is too big wastes energy and shuts off before it has dried the air. This calculator sizes a room unit from the room area, ceiling height, sunlight and occupants, and gives the answer in BTU per hour, kilowatts and tons.

Work out the heating or cooling capacity your room needs, in BTUs, from its size, ceiling height, sunlight, climate and how many people use it — so you buy an air conditioner or heater that is the right size, not an oversized one.

The 20 BTU per sq ft rule assumes an 8 ft ceiling; taller rooms scale up in proportion.

Each regular occupant beyond two adds 600 BTU/hr.

Cooking adds a lot of heat, so a kitchen needs 4,000 BTU/hr more.

Recommended Size

Save to Pinterest
Note: These are rule-of-thumb sizes for a single room, not a standard. Cooling follows the ENERGY STAR room air conditioner sizing rule (20 BTU/hr per sq ft at an 8 ft ceiling, with the adjustments below). Heating uses a contractor rule of thumb — 30 to 60 BTU/hr per sq ft by climate — and is a rough estimate only. Central and whole-home systems need a professional ACCA Manual J load calculation, and oversizing a unit wastes energy: a too-big air conditioner short-cycles and dehumidifies poorly.

How It Works

BTU per hour measures how much heat a unit can move in an hour — cooling removes heat from the room, heating adds it. For cooling, the ENERGY STAR room air conditioner sizing rule starts at 20 BTU/hr for every square foot of floor area, assuming an 8 ft ceiling and average insulation. That base is then adjusted: a very sunny room adds 10%, a heavily shaded room subtracts 10%, each regular occupant beyond two adds 600 BTU/hr, and a kitchen adds 4,000 BTU/hr for cooking heat. A taller ceiling scales the base by ceiling height ÷ 8, because there is more air to cool.

For heating, contractors use a rough rule of thumb that depends on climate: 30 BTU/hr per sq ft in a mild climate, 40 in a moderate one, 50 where winters are cold and 60 where they are very cold. That is an estimate for a single room, not a design standard — insulation, windows and air leaks move the real number a lot, which is why whole-home systems are sized by a Manual J load calculation instead.

The result is also shown in kilowatts (1 BTU/hr = 0.000293071 kW) and in tons of cooling (12,000 BTU/hr = 1 ton), the two units air conditioners are usually sold by.

Worked Examples

Cooling, 200 sq ft, average sun, 2 people, 8 ft ceiling: 200 × 20 = 4,000 BTU/hr (0.33 tons, 1.17 kW). A 400 sq ft room with the same conditions needs 8,000 BTU/hr.

Cooling adjustments on the 200 sq ft room: very sunny: 4,000 × 1.10 = 4,400 BTU/hr. A kitchen: 4,000 + 4,000 = 8,000 BTU/hr. Four regular occupants: 4,000 + 2 × 600 = 5,200 BTU/hr.

Cooling, 300 sq ft, 10 ft ceiling: 300 × 20 × (10 ÷ 8) = 7,500 BTU/hr.

Heating, 200 sq ft: moderate climate: 200 × 40 = 8,000 BTU/hr. Very cold climate: 200 × 60 = 12,000 BTU/hr (1 ton, 3.52 kW).

Assumptions

Last reviewed: 15 November 2026.

Built and tested by SumKitTool — see how we check our numbers.

How to Use This Calculator

Choose cooling or heating, enter the room area and conditions. The recommended size updates live as you type.

  1. Choose cooling or heating — cooling sizes an air conditioner, heating sizes a heater.
  2. Enter the room area in square feet — use the Square Footage Calculator if you only have the length and width.
  3. Set the conditions — ceiling height, sunlight, occupants and kitchen for cooling; climate for heating — then read the BTU/hr in the headline and the kW and tons in the table.

The Reset button restores the worked example (200 sq ft cooling, average sun, 2 people, 8 ft ceiling: 4,000 BTU/hr).

Tips and Practical Advice

Frequently Asked Questions

How many BTU do I need per square foot?

For cooling, the ENERGY STAR room air conditioner rule is 20 BTU/hr per square foot, assuming an 8 ft ceiling and average insulation — so a 200 sq ft room needs about 4,000 BTU/hr before adjustments. For heating, contractors use a rough rule of thumb of 30 to 60 BTU/hr per square foot depending on climate.

What does 12,000 BTU mean in tons?

One ton of cooling equals 12,000 BTU/hr, so a 12,000 BTU/hr unit is a 1-ton unit. A 4,000 BTU/hr room unit is about 0.33 tons. In kilowatts, 12,000 BTU/hr is about 3.52 kW.

Does ceiling height change the BTU I need?

Yes — the 20 BTU/hr per square foot rule assumes an 8 ft ceiling, so taller rooms scale by ceiling height divided by 8. A 300 sq ft room with a 10 ft ceiling needs 300 × 20 × (10 ÷ 8) = 7,500 BTU/hr.

Why shouldn't I just buy a bigger air conditioner?

An oversized air conditioner cools the room quickly and shuts off before it has run long enough to dehumidify the air, so the room feels cold and clammy while using more energy. Size to the room, and for a whole home get a professional ACCA Manual J load calculation instead of a rule of thumb.

Last updated: